Plugin "WP_KM"

Analyse von Wärmepumpen und Kältemaschinen

Definition

id
"Freigabe"
plugin_input_type
Meterlist
is_optional
True
label
"Freigabe"
min_input
0
max_input
1
allowed_units
Boolean
id
"Betrieb"
plugin_input_type
Meterlist
is_optional
False
label
"Betrieb"
min_input
1
max_input
1
allowed_units
Boolean
id
"Sollwert-Verdampfer"
plugin_input_type
Meterlist
is_optional
True
label
"Sollwert Verdampfer"
min_input
0
max_input
1
allowed_units
Temperature
id
"Sollwert-Kondensator"
plugin_input_type
Meterlist
is_optional
True
label
"Sollwert Kondensator"
min_input
0
max_input
1
allowed_units
Temperature
id
"Sollwert-Leistung"
plugin_input_type
Meterlist
is_optional
True
label
"Sollwert Leistung"
min_input
0
max_input
1
allowed_units
Percent
id
"Kompressor"
plugin_input_type
Meterlist
is_optional
True
label
"Kompressor"
min_input
0
max_input
4
allowed_units
Boolean
id
"Kompressor-_p_"
plugin_input_type
Meterlist
is_optional
True
label
"Kompressor [%]"
min_input
0
max_input
4
allowed_units
Percent
id
"Kompressor-Stufe-_MS_"
plugin_input_type
Meterlist
is_optional
True
label
"Kompressor Stufe [MS]"
min_input
0
max_input
8
allowed_units
Percent
id
"Austrittstemperatur-Verd_"
plugin_input_type
Meterlist
is_optional
True
label
"Austrittstemperatur Verd."
min_input
0
max_input
1
allowed_units
Temperature
id
"Eintrittstemperatur-Verd_"
plugin_input_type
Meterlist
is_optional
True
label
"Eintrittstemperatur Verd."
min_input
0
max_input
1
allowed_units
Temperature
id
"Pumpe-Verd_"
plugin_input_type
Meterlist
is_optional
True
label
"Pumpe Verd."
min_input
0
max_input
2
allowed_units
Boolean
id
"Ventil-Verd_"
plugin_input_type
Meterlist
is_optional
True
label
"Ventil Verd."
min_input
0
max_input
1
allowed_units
Percent
id
"Austrittstemperatur-Kond_"
plugin_input_type
Meterlist
is_optional
False
label
"Austrittstemperatur Kond."
min_input
1
max_input
1
allowed_units
Temperature
id
"Eintrittstemperatur-Kond_"
plugin_input_type
Meterlist
is_optional
False
label
"Eintrittstemperatur Kond."
min_input
1
max_input
1
allowed_units
Temperature
id
"Pumpe-Kond_"
plugin_input_type
Meterlist
is_optional
True
label
"Pumpe Kond."
min_input
0
max_input
2
allowed_units
Boolean
id
"Ventil-Kond_"
plugin_input_type
Meterlist
is_optional
True
label
"Ventil Kond."
min_input
0
max_input
1
allowed_units
Percent
id
"WRG-Betrieb"
plugin_input_type
Meterlist
is_optional
True
label
"WRG Betrieb"
min_input
0
max_input
1
allowed_units
Boolean
id
"WRG-Eintrittstemperatur"
plugin_input_type
Meterlist
is_optional
True
label
"WRG Eintrittstemperatur"
min_input
0
max_input
1
allowed_units
Temperature
id
"WRG-Austrittstemperatur"
plugin_input_type
Meterlist
is_optional
True
label
"WRG Austrittstemperatur"
min_input
0
max_input
1
allowed_units
Temperature
id
"WRG-Ventil"
plugin_input_type
Meterlist
is_optional
True
label
"WRG Ventil"
min_input
0
max_input
1
allowed_units
Percent
id
"WRG-Pumpe"
plugin_input_type
Meterlist
is_optional
True
label
"WRG Pumpe"
min_input
0
max_input
1
allowed_units
Boolean
id
"AT-Meteomatics"
plugin_input_type
Meterlist
is_optional
True
label
"AT Meteomatics"
min_input
0
max_input
1
allowed_units
Temperature

Schedule

recurrence
Day
data_range
Day
data_range_count
6